Schools & Offices

Schools & Offices | Shop now | Available only at SurgiMac

40 products

  • Sale -9% Self Seal Sterilization Pouches by MARK3 Self Seal Sterilization Pouches by MARK3

    MARK3 Self Seal Sterilization Pouches by MARK3

    Self Sealing Sterilization Pouches by MARK3 have built-in, easy to read, color changing internal indicators for steam and EiO gas. They are made with self-seal adhesive strips and triple sealed seams to keep out contaminants and maintain the sealed pouch within.Contains: 200/bx Product Specifications MARK3 Self Sealing Sterilization Pouches 200/bx  Sterilization pouches are ideal for sterilizing medical, dental and tattoo instruments. Each pouch has two (2) large built-in indicators for steam and EiO Gas which will change color when the optimum temperature is reached. They are made with self-seal adhesive strips and triple-sealed seams to keep out contaminants and maintain the sealed pouch within.

    SKU: 100-6120

    $4.29 - $57.85

  • Sale -5% MARK3 Self Sealing Sterilization Pouches 200/bx MARK3 Self Sealing Sterilization Pouches 200/bx

    MARK3 MARK3 Self Sealing Sterilization Pouches 200/bx

    Self Sealing Sterilization Pouches by MARK3 have built-in, easy to read, color changing internal indicators for steam and EiO gas. They are made with self-seal adhesive strips and triple sealed seams to keep out contaminants and maintain the sealed pouch within.Contains: 200/bx Product Specifications MARK3 Self Sealing Sterilization Pouches 200/bx  Sterilization pouches are ideal for sterilizing medical, dental and tattoo instruments. Each pouch has two (2) large built-in indicators for steam and EiO Gas which will change color when the optimum temperature is reached. They are made with self-seal adhesive strips and triple-sealed seams to keep out contaminants and maintain the sealed pouch within.

    SKU: 100-6121

    $60.99 $57.85

  • Sale -24% Thermal Paper Roll For Minibio, 3Rl/Bg

    Terragene Thermal Paper Roll For Minibio, 3Rl/Bg

    ICTP Mini / Thermal Paper specially designed for using with Bionova® Mini Bio, Bionova® Mini Pro Auto-Reader€™s Printer.Thermal Paper specially designed for using with Bionova® Mini Bio, Bionova® Mini Pro Auto-Reader€™s Printer. Specifications: Thermal Paper Roll. Color: White Paper Length: 4.7 m. Paper Width: 57 mm. Roll External Diameter: 23 mm. Roll Internal Diameter: 13.4 mm. Its function is to record the final results of biological indicators subjected to sterilization process and quantitative analysis of hygiene monitoring systems at each activated position of Bionova® Mini Bio and Mini Pro incubators, which allows record keeping in your sterilization records book. Read Bionova® Mini Bio and Mini Pro directions for use, as appropriate.

    SKU: ICTP MINI

    $40.99 $30.99

  • Sale -25% Thermal Paper Roll For IC10/20FR And IC10/20FRLCD, 6rl/Bg

    Terragene Thermal Paper Roll For IC10/20FR And IC10/20FRLCD, 6rl/Bg

    ICTP / Incubator Thermal Paper. Accessory for the IC10/20FR and IC10/20FRLCD incubator€™s thermal printer. Thermal Paper specially designed for using with Bionova® IC10/20FR, and Bionova® IC10/20FRLCD Auto-Reader€™s Printer. Specifications: Thermal Paper Roll. Color: white Paper length: 30 m. Paper width: 57 mm. Roll external diameter: 50 mm. Roll internal diameter: 13.4 mm. Its function is to record the final results of biological indicators subjected to sterilization process and quantitative analysis of hygiene monitoring systems at each activated position of IC10/20FR or IC10/20FRLCD, which allows registration into your sterilization record keeping book. Read IC10/20FR or IC10/20FRLCD directions for use, as appropriate.

    SKU: ICTP_BION_6

    $50.99 $37.99

  • Sale -19% Strip Integrator Steam, 500/Bg Strip Integrator Steam, 500/Bg

    Terragene Strip Integrator Steam, 500/Bg

    Multi-variable Chemical Indicator printed with reactive ink for Steam sterilization processes. Chemdye® CD29 Multivariable Process Indicators (Type 4 according to ISO 11140-1:2014 standard) are single-use chemical indicators that consist of one-side laminated punched paper double strips printed with indicator ink. These indicators have been designed to monitor Steam sterilization processes within loads, ensuring an adequate exposure to the sterilizing agent during the sterilization process and allowing to distinguish between processed and unprocessed items. Innovative highly sensitive yellow ink was developed to turn to dark brown/black when the indicator is exposed to Steam considering the critical process variables which provides additional quality assurance. Endpoint condition: 121 °C, 15 minutes; 134 °C, 3.5 minutes. Indicators 100 % free of toxic heavy metals. Instructions For Use: Place a Chemdye® CD29 Multivariable Process Indicator within each package, bag or tray that will be sterilized by Steam. In rigid containers, place the indicator in every corner, or at least two diagonally opposite corners, to ensure that the sterilization agent has reached the most inaccessible areas. Perform the sterilization cycle. After the sterilization process has finished, remove the indicators from the sterilizer and analyze the results. For all the chemical indicators exposed to Steam, the ink must turn to the dark brown/black reference color when the sterilization parameters are reached. For reference color, please refer to Result Reference Guide. Specifications: Process: Steam Initial Color: Yellow Final Color; Black Indicator Type: Type 4 chemical indicator Regulations: ISO 11140-1 More Info About This Product: Color Chart

    SKU: CD29

    $15.99 $12.99

  • Sale -24% Strip Integrator EO, 500/Bg Strip Integrator EO, 500/Bg

    Terragene Strip Integrator EO, 500/Bg

    CD16 / Multi-variable Chemical Indicators, double card strips printed with reactive ink for Ethylene Oxide sterilization processes. Metals Free. Control of Ethylene Oxide (EO) sterilization processes. Conditions: 600 mg/l EO, RH 60%, 30 °C, 30 minutes // 600 mg/l EO, RH 60%, 54 °C, 20 minutes. Characteristics: Type 4 Chemical Indicator (according to ISO 11140-1). Double punched card strips printed with indicator ink. Specifications: Size: 200 x 15 mm. Initial Color: Purple/Brown. Final Color: Green. 100 % Toxic Heavy Metals free. Instructions For Use: Place a Chemdy® CD16 Multivariable Process Indicator within each package, bag or tray that will be sterilized by Ethylene Oxide. In rigid containers, place the indicator in every corner, or at least two diagonally opposite corners, to ensure mthat the sterilization agent has reached the most inaccessible areas. Perform the sterilization cycle. After the sterilization process has finished, remove the indicators from the sterilizer and analyze the results. For all the chemical indicators exposed to Ethylene Oxide, the ink must turn to the green reference color when the sterilization parameters are reached. More Info About This Product: Color Chart

    SKU: CD16

    $20.99 $15.90

  • Sale -15% PCD, Ultra Rapid W/BI (20Min) For Steam, 25 Bis + 25 PCDs/Kt PCD, Ultra Rapid W/BI (20Min) For Steam, 25 Bis + 25 PCDs/Kt

    Terragene PCD, Ultra Rapid W/BI (20Min) For Steam, 25 Bis + 25 PCDs/Kt

    KPCD224-C / Test Pack PCD Kit. Process Challenge Device for Steam sterilization processes with moving-front Type 5 Integrator and Bionova® Ultra Rapid Self-contained Biological Indicator BT224, plus Bionova® BT224 Biological Indicators Positive Control. Class 5 spores per strip. For routine load release, especially for loads containing implants. For routine sterilizer monitoring. For periodic validation of the sterilizer (after installation, repair, relocation). Detects inadequate air removal and steam penetration in dynamic- airremoval (pre-vacuum) and gravity displacement, steam autoclaves between 132-135 ºC. Characteristics: The kit Consists Of: PCD224-C: Porous Cards System Holding: A Self-contained Biological Indicator Bionova® BT224.A Type 5 chemical indicator Integron® IT26-C (moving-front integrator). A self-adhesive Record Card, PCDBI-C-RC, where data on sterilization cycle may be written. Self-contained Biological Indicator Bionova® BT224 (to be used as a positive control) Specifications: Initial Color: Blue. Final Color: Dark Grey or Black. Process: Steam Microorganism: Geobacillus stearothermophilus (ATCC 7953) Population: 10^6 Spores/carrier Read-Out Time: 20 min Regulations: ANSI/AAMI ST79, ISO 11138-3, ISO 11140-1 IT26-C Integrator Indicator (within the challenge device): The migration is visible through a zone marked ACCEPT or REJECT, thus indicating whether sterilization conditions were met. Integration condition is calibrated against the kill time of a 106 G. stearothermophilus ATCC 7953 spore population, calculated in BIER (Biological Indicator Evaluator Resistometer). Conditions: saturated steam at 121 ºC, 128 ºC, 135 ºC. BT224 Self-contained Ultra Rapid Biological Indicator (within the challenge device): 106 G. stearothermophilus ATCC 7953 spores per vial in paper carrier. Glass ampoule with growth indicator medium. Label with chemical indicator line printed with Steam reactive ink (Color change: pink to brown) Final results: by fluorescence after incubation for 20 minutes at 60 ºC (sensitivity 97%). An optional visual pH color change confirmation could be made after 48 hours of incubation. A 7-day readout is optional to confirm 20-minutes results by color change. Note: If sterilization process was not successful, indicator medium will turn yellow after incubation, thus indicating the presence of living G. stearothermophilus spores. If sterilization process was successful, indicator medium will remain purple after incubation.

    SKU: KPCD224-C

    $260.99 $220.99

  • Sale -15% PCD Kit For Steam With BI (1h), IT26-C Integrator Indicator, 25 Bis + 25 PCD/Kt PCD Kit For Steam With BI (1h), IT26-C Integrator Indicator, 25 Bis + 25 PCD/Kt

    Terragene PCD Kit For Steam With BI (1h), IT26-C Integrator Indicator, 25 Bis + 25 PCD/Kt

    KPCD222-C / Test Pack PCD Kit. Process Challenge Device for Steam sterilization processes with moving-front Type 5 Indicator and Bionova® Super Rapid Self-contained Biological Indicator BT222, plus Bionova® BT222 Biological Indicators Positive Control. For routine load release, especially for loads containing implants. For routine sterilizer monitoring. For periodic validation of the sterilizer (after installation, repair, relocation). Detects inadequate air removal and steam penetration in dynamic-airremoval (pre-vacuum) and gravity displacement steam autoclaves between 121-135 ºC. Characteristics: The Kit Consists Of: PCD222-C: Porous cards system holding: A Self-contained Biological Indicator Bionova® BT222. A Type 5 chemical indicator Integron® IT26-C (moving-front integrator). A self-adhesive Record Card, PCDBI-C-RC, where data on sterilization cycle may be written. Self-contained Biological Indicator Bionova® BT222 (to be used as a positive control) Specifications: Initial Color: Blue Final Color: Dark Grey or Black Process: Steam Microorganism: Geobacillus stearothermophilus (ATCC 7953) Population: 10^6 Spores/carrier Read-Out Time: 1 h Regulations: ANSI/AAMI ST79, ISO 11138-1, ISO 11138-3 IT26-C Chemical Integrator (within the challenge device) The migration is visible through a zone marked ACCEPT or REJECT, thus indicating whether sterilization conditions were met. Integration condition is calibrated against the kill time of a 106 G. stearothermophilus ATCC 7953 spores€™ population, calculated in BIER (Biological Indicator Evaluator Resistometer). Conditions: saturated steam at 121 °C, 128 °C, 135 °C. BT222 Super Rapid Self-contained Biological Indicator (within the challenge device): ‰¥106 G. stearothermophilus ATCC 7953 spores per vial in paper carrier. Glass ampoule with growth indicator medium. Label with chemical indicator line printed with Steam reactive ink (Color change: pink to brown)

    SKU: KPCD222-C

    $240.99 $205.99

  • Sale -17% Steam Indicator Tape Roll Steam Indicator Tape Roll

    Terragene Steam Indicator Tape Roll

    CT22 / Indicator Tape for Steam sterilization processes. Cintape® CT22 Process Indicators (Type 1 according ISO 11140-1:2014 standard) are single-use chemical indicators that consist of a roll of self-adhesive paper tape printed with indicator ink. These indicators have been designed to monitor Steam sterilization processes, ensuring an adequate exposure to the sterilizing agent during the sterilization process and allowing to distinguish between processed and unprocessed items. The adhesive component of the tape allows the adhesion to different types of packaging and wraps, such as cloth, paper and plastic being easy to remove and leaving no residues. Innovative highly sensitive yellow ink was developed to turn to dark brown / black when the indicator is exposed to Steam. Endpoint condition: 121 ºC, 10 minutes; 134 ºC, 2 minutes. Instructions For Use: Place within a sterilizer a wrapped package closed with Cintape® CT22 Process Indicator tape that will be sterilized by Steam. Perform the sterilization cycle. After the sterilization process has finished, remove the package from the sterilizer and analyze the indicator results. The indicator must turn to the reference color for considering that it was exposed to Steam. For reference color, please refer to Result Reference Guide. Specifications: Process: Steam Initial Color: Yellow Final Color: Black, Dark Brown Indicator Type: Type 1 chemical indicator Regulations: ISO 11140-1 More Info About This Product: Color Chart

    SKU: CT22

    $5.99 $4.99

  • Sale -21% Hydrogen Peroxide Indicator Tape

    Terragene Hydrogen Peroxide Indicator Tape

    Indicator Tape for Plasma or Vaporized Hydrogen Peroxide Sterilization Processes. Cintape® CT40 Process Indicators (Type 1 according ISO 11140-1:2014 standard) are single-use chemical indicators that consist of a roll of self-adhesive plastic tape printed with indicator ink. These indicators have been designed to monitor Plasma or Vaporized Hydrogen Peroxide sterilization processes, ensuring adequate exposure to the sterilizing agent during the sterilization process and allowing to distinguish between processed and unprocessed items. The adhesive component of the tape allows the adhesion to different types of packaging and wraps, such as cloth, paper and plastic being easy to remove and leaving no residues. Innovative highly sensitive purple ink was developed to turn to green when the indicator is exposed to Plasma or Vaporized Hydrogen Peroxide. Endpoint condition: 50 ºC, 6 minutes, 2.3 mg/l H2O2. Indicators 100 % free of toxic heavy metals. Instructions For Use: Place within a sterilizer a wrapped package closed with Cintape® CT40 Process Indicator tape that will be sterilized by Plasma or Vaporized Hydrogen Peroxide. Perform the sterilization cycle. After the sterilization process has finished, remove the package from the sterilizer and analyze the indicator results. The indicator must turn to the reference color for considering that it was exposed to Plasma or Vaporized Hydrogen Peroxide. For reference color, please refer to Result Reference Guide. Specifications: Process: Hydrogen Peroxide Initial Color: Purple Final Color: Green Indicator Type: Type 1 chemical indicator Regulations: ISO 11140-1

    SKU: CT40

    $18.99 $14.99

  • Sale -19% Fluorescence Ultra Rapid SCBI For H2O2. 60°C (30 minutes), 50/Bx Fluorescence Ultra Rapid SCBI For H2O2. 60°C (30 minutes), 50/Bx

    Terragene Fluorescence Ultra Rapid SCBI For H2O2. 60°C (30 minutes), 50/Bx

    Super Rapid Self-contained Biological Indicator for Plasma or Vaporized Hydrogen Peroxide Sterilization Processes. Final readout: 30 minutes. An optional visual pH color change confirmation could be performed after 48 hours of incubation. If sterilization process has not been successful, culture medium will change to yellow during incubation at 60 ºC, thus showing the presence of living spores. If sterilization process is successful culture medium will remain purple after the incubation process. 7-day readout is optional and not intended to be routinely performed; it is an initial validation of the 30-minute reading. Fluorescence results may be compared to the 7-day visual reading. Note: If 7-day readout is performed, a humidified environment will be required to prevent medium from drying out. Instructions For Use: Identify the Terragene® Bionova® BT96 SCBI by writing the sterilizer number (in case of having more than one), load number and processing date on the label. Pack the SCBI along with materials to be sterilized in an appropriate package according to recommended sterilization practices. Place the package in those areas which are considered most inaccessible for the sterilizing agent (e.g., the center of the load and areas near the door). Sterilize as usual. After the sterilization process has finished, open the sterilizer door, wait five minutes and remove the SCBI from the package. CAUTION: Wear safety glasses and gloves when removing the Terragene® Bionova® BT96 SCBI from the sterilized package.( Do not crush or handle the SCBI excessively, since this might cause the glass ampoule to burst. Let the SCBI cool down until it reaches room temperature.) Check the Process Indicator on SCBI label. A color change to green indicates that the SCBI has been exposed to Hydrogen Peroxide. IMPORTANT: This color change does not evidence the process effectiveness to achieve sterility. If the color of the Process Indicator has not changed, check the sterilization process. 6. Press the lid to seal the tube. Crush the ampoule contained in the SCBI with an individual ampoule crusher or with the ampoule crusher placed within the incubator´s incubation area. Then shake the tube down vigorously, with movements similar to those performed to lower the temperature in a mercury thermometer, until the medium reaches the base of the tube and soaks the spore carrier entirely. Finally, place the SCBI in the incubator. Incubate the processed indicator and the positive control indicator in the appropriate Terragene® Bionova® Auto-Reader incubators for a maximum of 30 minutes at (60 ± 2) °C for super rapid readout. Important: Use a non-sterilized SCBI as a positive control at least once per day, when a sterilization cycle is run. The positive control ensures that correct incubation conditions were met; the capability of the medium to promote rapid growth; viability of spores has not been altered due to improper storage temperature, humidity or proximity to chemicals and proper functioning of Terragene® Bionova® Auto-Reader Incubators. Both, the positive control indicator and the processed indicator, should belong to the same batch. Note: Holding time between sterilization and incubation should not exceed a 7-day period. Fluorescence detection by the reader (excitation 340-380 nm / emission 455-465 nm) means failure in the sterilization process. If no fluorescence is detected after 30 minutes of incubation, the result is negative. The positive control must give positive fluorescence readout. It is good practice to incubate a positive control for visual color change. Specifications: Process: Hydrogen peroxide Microorganism: Geobacillus stearothermophilus (ATCC 7953) Population: 10^6 Spores/carrier Read-Out Time: 30 min Regulations: IRAM 37102-1, ISO 11138-1

    SKU: BT96

    $390.99 $315.99

  • Sale -12% Fluorescence SCBI For Steam. 60°C (20 minutes), Ultra Rapid, 50/bx Fluorescence SCBI For Steam. 60°C (20 minutes), Ultra Rapid, 50/bx

    Terragene Fluorescence SCBI For Steam. 60°C (20 minutes), Ultra Rapid, 50/bx

    Ultra Rapid Self-contained Biological Indicator for Steam sterilization processes. Geobacillus stearothermophilus (ATCC 7953) 10^6 spores per vial. Readout: 20 minutes. An optional visual pH color change confirmation could be made after 48 hours of incubation. If the sterilization process has not been successful, the culture medium will change to a greenish color first, and then to yellow during incubation at 60 ºC, thus showing the presence of living spores. If the sterilization process is successful culture medium will remain purple after the incubation process. 7-day readout is optional and not intended to be routinely performed; it is an initial validation of the 20 minute-reading. Fluorescence results may be compared to the 7-day visual reading. Note: If 7-day readout is performed, a humidified environment will be required to avoid medium to dry out. D-Value: Not lower than 1.5 minutes at 121 ºC. Another D-value is informed at 132ºC and at 135ºC. Z-Value is informed. Instructions For Use: Identify the Terragene® Bionova® BT224 SCBI by writing the sterilizer number (in case of having more than one), load number and processing date on the label. Pack the SCBI along with materials to be sterilized in an appropriate package according to recommended sterilization practices. Place the package in those areas which are considered most inaccessible for the sterilizing agent (e.g., the center of the load and areas near the door). Sterilize as usual. After the sterilization process has finished, open the sterilizer door, wait five minutes and remove the SCBI from the package. CAUTION: Wear safety glasses and gloves when removing the Terragene® Bionova® BT224 SCBI from the sterilized package. (Do not crush or handle the SCBI excessively, since this might cause the glass ampoule to burst. Let the SCBI cool down until it reaches room temperature.) 5. Check the Process Indicator on SCBI label. A color change to brown indicates that the SCBI has been exposed to Steam. ( This color change does not evidence the process effectiveness to achieve sterility. If the Process Indicator color has not changed, check the sterilization process.) 6. Press the lid to seal the tube. Crush the ampoule contained in the SCBI with an individual ampoule crusher or with the ampoule crusher placed within the incubator´s incubation area. Then shake the tube down vigorously, with movements similar to those performed to lower the temperature in a mercury thermometer, until the medium reaches the base of the tube and soaks the spore carrier entirely. Finally, place the SCBI in the incubator. 7. Incubate the processed indicator and the positive control indicator in the appropriate Terragene® Bionova® Auto-Reader Incubators for a maximum of 20 minutes at (60 ± 2) °C for ultra rapid readout. Important: Use a non-sterilized SCBI as a positive control at least once per day, when a sterilization cycle is run. The positive control ensures that correct incubation conditions were met; capability of medium to promote rapid growth; viability of spores has not been altered due to improper storage temperature, humidity or proximity to chemicals and proper functioning of Terragene® Bionova® Auto-Reader Incubators. Both, the positive control indicator and the processed indicator, should belong to the same batch. Note: Holding time between sterilization and incubation should not exceed a 7-day period. Fluorescence detection by the reader (excitation 340-380 nm / emission 455-465 nm) means a failure in the sterilization process. If no fluorescence is detected at 20-minute incubation, the result is negative. The positive control must give positive fluorescence readout. It is good practice to incubate a positive control for a visual color change.

    SKU: BT224

    $290.99 $255.99

  • Sale -14% Fluorescence Hyper Rapid SCBI For H2O2. 60°C (5 minutes), 50/Bx Fluorescence Hyper Rapid SCBI For H2O2. 60°C (5 minutes), 50/Bx

    Terragene Fluorescence Hyper Rapid SCBI For H2O2. 60°C (5 minutes), 50/Bx

    Hyper Rapid Self-contained Biological Indicator for Vaporized Hydrogen Peroxide sterilization processes. Final readout: 5 minutes. Indications For Use: Terragene® Bionova® BT98 fluorescence hyper rapid readout Biological Indicators have been designed for quick and easy monitoring of Plasma or vaporized hydrogen Peroxide sterilization cycles. Device Description: Terragene® Bionova® BT98 fluorescence hyper rapid readout Biological Indicators are single-use Self-Contained Biological Indicators (SCBIs) that consist of a polypropylene tube, a spore carrier and a glass ampoule with a culture medium, enclosed with a colored cap. Each tube contains a population of Geobacillus stearotermophilus ATCC 7953 spores inoculated on a spore carrier, a plastic cap with holes and a barrier permeable to Plasma or Vaporized Hydrogen Peroxide. Each BT98 has a Process Indicator on label that changes from purple to green when exposed to hydrogen peroxide. Precautions: Warning: Do not use Terragene® Bionova® BT98 SCBI to control EO, Dry Heat, Formaldehyde or other sterilization processes different from specified. Do not reuse SCBI. Warning:  Place one or more SCBI in sterilizing hard-to-reach areas to ensure all areas of the chamber are sterilized. Please evaluate all load configurations to ensure ALL hard-to-reach areas have been identified, and place a SCBI in each of those locations. Warning:  Do not reuse the sterilizer until the SCBI test result is negative. Instructions For Use: Identify the Terragene® Bionova® BT98 SCBI by writing the sterilizer number (incase of having more than one), load number and processing date on the label. Pack the SCBI along with materials to be sterilized in an appropriate package according to recommended sterilization practices. Place the package in those areas which are considered most inaccessible for the sterilizing agent (e.g., the center of the load and areas near the door). Sterilize as usual. After the sterilization process has finished, open the sterilizer door, wait five minutes and remove the SCBI from the package. Caution Wear safety glasses and gloves when removing the Terragene® Bionova® BT98 SCBI from the sterilized package. ( Do not crush or handle the SCBI excessively, since this might cause the glass ampoule to burst. Let the SCBI cool down until it reaches room temperature.) Check the Process Indicator on SCBI label. A color change to green indicates that the SCBI has been exposed to Hydrogen Peroxide. IMPORTANT: This color change does not evidence the process effectiveness to achieve sterility. If the color of the Process Indicator has not changed, check the sterilization process. Press the lid to seal the tube. Crush the ampoule contained in the SCBI with an individual ampoule crusher or with the ampoule crusher placed within the incubator´s incubation area. Then shake the tube down vigorously, with movements similar to those performed to lower the temperature in a mercury thermometer, until the medium reaches the base of the tube and soaks the spore carrier entirely. Finally, place the SCBI in the incubator. Incubate the processed indicator and the positive control indicator in the appropriate Terragene® Bionova® auto-reader incubators for a maximum of 5 minutes at (60 ± 2) °C for hyper rapid readout. (Holding time between sterilization and incubation should not exceed a 1-hour period.) Important: Use a non-sterilized SCBI as a positive control at least once per day, when a sterilization cycle is run. The positive control ensures that correct incubation conditions were met; the capability of the medium to promote rapid growth; viability of spores has not been altered due to improper storage temperature, humidity or proximity to chemicals and proper functioning of Terragene® Bionova® Auto-Reader Incubators. Both, the positive control indicator and the processed indicator, should belong to the same batch. Fluorescence detection by the reader (excitation 340-380 nm / emission 455-465 nm) means failure in the sterilization process. If no fluorescence is detected after 5 minutes of incubation, the result is negative. The positive control must give positive fluorescence readout. It is good practice to incubate a positive control for visual color change. Record positive results and discard the SCBIs immediately, as it is indicated below. Hyper Rapid Readout: 5 minutes The hyper rapid readout must be carried out in the appropriate Terragene® Bionova® auto-reader incubators. Fluorescence is emitted after the reader stimulates the spore carrier with UV light. Final readout of negative results is readily available after 5 minutes of incubation. Fluorescence readout is an indirect measure of the viability of Geobacillus stearothermophilus spores after the sterilization process (positive results). Furthermore, a failure in the sterilization process can also become evident by culture medium color-change. Due to the high sensitivity of the fluorescence results at 5 minutes, conventional incubation for color change of Terragene® Bionova® SCBI BT98 is not an advantage. Visual Confirmation: 5 days: Optionally, you can perform a visual color-change confirmation after a 5-day incubation. If the sterilization process has not been successful, culture medium will turn to yellow during incubation at (60 ± 2) ºC, indicating the presence of living spores. If sterilization was successful, culture medium will remain purple after incubation. The positive control must show a color change from purple to yellow for results to be valid. ( If 5-day readout is performed, a humidified environment will be required to prevent medium from drying out.) Readout Time: 7 days A 7-day readout is optional and may be routinely performed. This is an initial validation of the 5-minute readout. Fluorescence results are compared to the 7-day visual readouts. Monitoring Frequency: Follow facility policies and procedures which should specify a biological indicator monitoring frequency compliant with professional association recommended practices and/or national guidelines and standards. As the best practice and to provide optimal patient safety, Terragene® recommends that every sterilization load be monitored with an appropriate biological indicator. Storage: Store in a dark place at temperature between 10-30 ºC and 30-80 % relative humidity. Do not freeze. Do not store biological indicators near sterilizing agents or other chemical products. Shelf Life: Biological Indicators have an expiration date of 2 years from the date of manufacture when stored at recommended conditions. Do not use indicators after their expiration date. Chemical Process Indicator on SCBI label have an expiration date of 2 years when used as part of SCBI. Endpoint Stability Reaction: Chemical Process Indicator endpoint shall remain unchanged for a period of 6 months when stored at previously indicated conditions. Disposal: Discard biological indicators after use according to your country’s healthcare and safety regulations. The positive biological indicators can be autoclaved in a gravity air displacement steam sterilizer at 121 ºC for 5 minutes, 132 ºC for 15 minutes or 134 ºC for 10 minutes; or in a dynamic air removal steam sterilizer at 132 °C for 4 minutes or 135 °C for 3 minutes. Specifications: Population: 10^6 Spores/carrier Read-Out Time: 5 min Regulations: IRAM 37102-1:1999, ISO 11138-1:2017, ISO 13485:2016 / NS-EN ISO 13485:2016

    SKU: BT98

    $590.99 $510.99

  • Sale -16% Fluorescence SCBI For EO, 37°C (4 hour), 50/Bx Fluorescence SCBI For EO, 37°C (4 hour), 50/Bx

    Terragene Fluorescence SCBI For EO, 37°C (4 hour), 50/Bx

    Rapid Self-contained Biological Indicator for Ethylene Oxide sterilization processes. Bacillus atrophaeus (ATCC 9372) 10^6 spores per vial. Readout: 4 hours. An optional visual pH color change confirmation could be made after 48 hours of incubation. If sterilization process has not been successful, culture medium will change to a greenish color first, and then to yellow during incubation at 37 ºC, thus showing the presence of living spores. If sterilization process is successful culture medium will remain blue after the incubation process. 7-day readout for visual confirmation by color change is optional and not intended to be routinely performed; it is an initial validation of the 4 hour-reading. Fluorescence results may be compared to the 7-day visual reading. Instructions For Use: Identify the Terragene® Bionova® BT110 SCBI by writing the sterilizer number (in case of having more than one), load number and processing date on the label. Pack the SCBI along with materials to be sterilized in an appropriate package according to recommended sterilization practices. Place the package in those areas which are considered most inaccessible for the sterilizing agent (e.g., the center of the load and areas near the door). Sterilize as usual. After the sterilization process has finished, open the sterilizer door, wait five minutes and remove the SCBI from the package. CAUTION: Wear safety glasses and gloves when removing the Terragene® Bionova® BT110 SCBI from the sterilized package. Check the Process Indicator on SCBI label. A color change to green indicates that the SCBI has been exposed to Ethylene Oxide. IMPORTANT: This color change does not evidence the process effectiveness to achieve sterility. If the color of the Process Indicator has not changed, check the sterilization process. Press the lid to seal the tube. Crush the ampoule contained in the SCBI with an individual ampoule crusher or with the ampoule crusher placed within the incubator´s incubation area. Then shake the tube down vigorously, with movements similar to those performed to lower the temperature in a mercury thermometer, until the medium reaches the base of the tube and soaks the spore carrier entirely. Finally, place the SCBI in the incubator. Incubate the processed indicator and the positive control indicator in the appropriate Terragene® Bionova® Auto-Reader incubators for a maximum of 4 hours at (37 ± 2) °C for rapid readout. Note: Holding time between sterilization and incubation should not exceed a 7-day period. Fluorescence detection by the reader (excitation 340-380 nm / emission 455-465 nm) means failure in the sterilization process. If no fluorescence is detected after 4 hours of incubation, the result is negative. The positive control must give positive fluorescence readout. It is good practice to incubate a positive control for visual color change. If chamber relative humidity is unknown or < 35 %, continue to incubate the Biological Indicator for a pH color change result, since low relative humidity may increase the fluorescent readout time beyond 4 hours. Specifications: Process: Ethylene Oxide Microorganism: Bacillus atrophaeus (ATCC 9372) Population: 10^6 Spores/carrier Read-Out Time: 4 h Regulations: IRAM 37102-1, IRAM 37102-2, ISO 11138-1, ISO 11138-2 Length: 40 mm

    SKU: BT110

    $250.99 $210.99

  • Sale -20% Fluorescence SCBI For Steam, 60°C (1h), 50/Bx Fluorescence SCBI For Steam, 60°C (1h), 50/Bx

    Terragene Fluorescence SCBI For Steam, 60°C (1h), 50/Bx

    Super Rapid Self-contained Biological Indicator for Steam sterilization processes. Geobacillus stearothermophilus (ATCC 7953) 10^6 spores per vial. Readout: 1 hour. An optional visual pH color change confirmation could be made after 48 hours of incubation. If sterilization process has not been successful, culture medium will change to a greenish color first, and then to yellow during incubation at 60 ºC, thus showing the presence of living spores. If sterilization process is successful culture medium will remain purple after the incubation process. 7-day readout is optional and not intended to be routinely performed; it is an initial validation of the 1 hour-reading. Fluorescence results may be compared to the 7-day visual reading. Note: if 7-day readout is performed, a humidified environment will be required to avoid medium to dry out. D-Value: Not lower than 1.5 minutes at 121 ºC. Another D-value is informed at 132 ºC and at 135 ºC. Z-Value is informed. Instructions For Use: Identify the Terragene® Bionova® BT222 SCBI by writing the sterilizer number (in case of having more than one), load number and processing date on the label. Pack the SCBI along with materials to be sterilized in an appropriate package according to recommended sterilization practices. Place the package in those areas which are considered most inaccessible for the sterilizing agent (e.g., the center of the load and areas near the door). Sterilize as usual. After the sterilization process has finished, open the sterilizer door, wait five minutes and remove the SCBI from the package. CAUTION: Wear safety glasses and gloves when removing the Terragene® Bionova® BT222 SCBI from the sterilized package. WARNING: Do not crush or handle the SCBI excessively, since this might cause the glass ampoule to burst. Let the SCBI cool down until it reaches room temperature. Check the Process Indicator on SCBI label. A color change to brown indicates that the SCBI has been exposed to Steam. IMPORTANT: This color change does not evidence the process effectiveness to achieve sterility. If the Process Indicator color has not changed, check the sterilization process. Press the lid to seal the tube. Crush the ampoule contained in the SCBI with an individual ampoule crusher or with the ampoule crusher placed within the incubator´s incubation area. Then shake the tube down vigorously, with movements similar to those performed to lower the temperature in a mercury thermometer, until the medium reaches the base of the tube and soaks the spore carrier entirely. Finally, place the SCBI in the incubator. Incubate the processed indicator and the positive control indicator in the appropriate Terragene® Bionova® Auto-Reader Incubators for a maximum of 1 hour at (60 ± 2) °C for super rapid readout. Specifications: Process: Steam Microorganism: Geobacillus stearothermophilus (ATCC 7953) Population: 10^6 Spores/carrier Read-Out Time: 1 h Regulations: IRAM 37102-1, IRAM 37102-3, ISO 11138-1, ISO 11138-3

    SKU: BT222

    $170.99 $136.99

  • Sale -15% Wash/Soil Test For Washers And Ultrasonics, 200 Strips/Bg Wash/Soil Test For Washers And Ultrasonics, 200 Strips/Bg

    Terragene Wash/Soil Test For Washers And Ultrasonics, 200 Strips/Bg

    CDWA4 / Cleaning Indicator for cleaning performance tests. Challenge level: very high. Detects all the factors that affect the result of a washing process. Initial Color: Fuchsia. Result: removal of the fuchsia organic substance. Designed for routine control of cleaning processes and for monitoring automatic washing machines effectiveness as well as monitoring ultrasonic washing machines which operate at frequencies equal to or greater than 35 kHz, and temperatures between 30 ºC and 70 ºC. Characteristics: Challenge Level: Very high. Allows detection of all factors affecting the outcome of cleaning process. Initial Color: Fuchsia. Size: 70 mm x 30 mm (approximate). Synthetic temperature-stable support. Result: Elimination of fuchsia organic substance. To interpret results visually, use the results reference guide on product´s instructions for use. Optionally, the readout of the cleaning indicator can be done using Trazanto Automatic Quality Control and Traceability System (see instructions for use in device´s manual). Instructions For Use: Choose the Chemdye® Splat CDWA indicator according to the desired difficulty. Place the indicator on the Chemdye® Splat CDWAH or Chemdye® Splat CDWAH-U holder. Place the system on the tray along with the material. Once the cleaning cycle is over, remove the indicator. Analyze Chemdye® Splat CDWA indicators using the reference table and record results. If unfavorable results are obtained, perform the appropriate corrective actions and repeat the washing process. Specifications: Process: Cleaning and thermodisinfection Initial Color: Fuchsia Regulations: ISO 13485, ISO/TS 15883-5

    SKU: CDWA4

    $95.99 $81.99

  • Sale -27% Holder For CDWU-Z Ultrasonic Cleaning Indicator Vials. 10/Bg Holder For CDWU-Z Ultrasonic Cleaning Indicator Vials. 10/Bg

    Terragene Holder For CDWU-Z Ultrasonic Cleaning Indicator Vials. 10/Bg

    Instructions For Use: Before The Test: Place the holder around the neck of the capsule. Press the holder down so that the groove of the holder fits securely around the neck of the vial. Insert the L shaped end on either side of the holder into the holes of the Ultrasonic device’s basket to hold the vial in position. The holder can be attached to a wire basket or perforated basket. Vials should be placed in the correct location within a tray / basket according to Ultrasonic Cleaning Indicator´s IFU based on the size of the tank. After the test is complete After the ultrasonic cycle remove the vial holding it with three fingers of one hand and the index finger and thumb of the other hand on the holder and lid of capsule. Place the index finger on the end of the holder, then place the thumb on the lid of the capsule for support, push the holder back off the neck of the capsule and remove the holder with both fingers.

    SKU: CDWU-H

    $36.99 $26.99

  • Sale -25% Holder For CDWA4 For Washers, 1/Bx Holder For CDWA4 For Washers, 1/Bx

    Terragene Holder For CDWA4 For Washers, 1/Bx

    Holder for cleaning and thermodisinfection Indicators. Stainless Steel re-usable holder of great resistance and durability. Base: 32 mm wide, 72 mm long, pin at the back side. ISO/TS 15883-5. Designed to hold Chemdye® CDWA and Integron® IT27W indicators in order to perform routine control of cleaning and thermal disinfection processes in automatic machines. Characteristics: Chrome plating SUS304 grade stainless steel re-usable holder of great resistance and durability. Base: 32 mm wide, 72.5 mm long, pin at the back side. Basket: 32 mm wide, 37 mm long, 0.5 mm thick. The holder is designed to mimic the cleaning challenges posed by a large process load during the washing cycle and can be fixed on the tray, which allows reproducible location of the cleaning indicator in the washer-disinfector. When CDWA4 is placed within the holder, half of the test soil is obscured, thus simulating the joint of a surgical instrument, with water stream hitting it indirectly. The other half of the test soil is covered by a mesh, thus posing a difficulty for water stream to reach it, mimicking shadowed or occluded surfaces. The new design of CDWAH optimizes the control of the washer disinfectors ability to force water and detergent into and onto the test soil. Specifications: Process: Cleaning and thermodisinfection Regulations: ISO 15883

    SKU: CDWA-H

    $35.99 $26.99

  • Sale -25% Holder For CDWA4 For Ultrasonics, 1/Bx Holder For CDWA4 For Ultrasonics, 1/Bx

    Terragene Holder For CDWA4 For Ultrasonics, 1/Bx

    CDWAH-U / Stainless steel re-usable holder of great resistance and durability. The holder is designed to be fixed on the tray, which allows reproducible location of the cleaning indicator in ultrasonic washing machines. Base: 32,7 mm wide, 72,5 mm long. Designed to hold Chemdye® CDWA cleaning indicators and perform routine control of cleaning processes in ultrasonic washers. Characteristics: Chrome plating SUS304 grade stainless steel re-usable holder of great resistance and durability. Base: 32 mm wide, 72.5 mm long, pin at the back side. The holder is designed to be fixed on the tray, which allows reproducible location of the cleaning indicator in ultrasonic washing machines, without representing a challenge to the washing process. Specifications: Process: Cleaning and thermodisinfection Regulations: ISO/TS 15883-5

    SKU: CDWAH-U

    $35.99 $26.99

  • Sale -12% Chemical Integrator, Steam, Single Point Type 5, 250/Bg Chemical Integrator, Steam, Single Point Type 5, 250/Bg

    Terragene Chemical Integrator, Steam, Single Point Type 5, 250/Bg

    IT26-1YS / Unique point chemical integrator for Steam sterilization processes between 121° C and 134° C. Control of Steam sterilization processes between 121 ºC and 135 ºC. Characteristics: Type 5 Integrator Indicator (according to ISO 11140-1). One-side-laminated strips printed with indicator ink. Size: 70 mm x 23 mm. Initial Color: Yellow. Final Color: Black. 100 % Toxic Heavy Metal free. Instructions For Use: Place a chemical integrator Integron® IT26-1YS within each package, bag or tray that will be sterilized by Steam. In rigid containers place an IT26-1YS in every corner, or at least two diagonally opposite corners, to ensure that steam has reached the most inaccessible areas. Perform the sterilization cycle. After the sterilization process has finished, remove the indicators from the sterilizer and analyze the results. For all the chemical indicators exposed to Steam, the ink must turn to the black reference color when the integration conditions are reached. Specifications: Process: Steam Initial Color: Yellow Final Color: Black Indicator Type: Type 5 chemical indicator Regulations: ISO 11140-1 More Info About This Product: Color Chart

    SKU: IT26-1YS

    $25.99 $22.99

  • Sale -16% Chemical Integrator, ETO, Level 2 Type 5, 250/Bg Chemical Integrator, ETO, Level 2 Type 5, 250/Bg

    Terragene Chemical Integrator, ETO, Level 2 Type 5, 250/Bg

    2 level chemical integrator for Ethylene Oxide sterilization processes. One-side laminated strips. Metals free. Integron® IT12 Chemical Integrators (Type 5 according to ISO 11140-1:2014 standard) are single-use two level chemical indicators that consist of paper strips laminated on the back side and printed with indicator ink. They have been designed for monitoring Ethylene Oxide (EO) sterilization processes. The integration level contains a purple/brown ink which was developed to turn to green when a theoretical spore population reaches its kill time, thus indicating that the SAFE condition has been met. Level 1 – Red: Exposure level. Indicator ink turns yellow to indicate exposition to the process, but does not ensure that the variables required to achieve the integration condition have been achieved (UNSAFE condition). Level 2 – Purple / brown: Integration level. Indicator ink turns green to indicate that the integration condition indicated in the quality certificate has been achieved. This condition consists of the kill time of a theoretical 106 Bacillus atrophaeus spore population, calculated in a BIER (Biological Indicator Evaluator Resistometer), and is called SAFE condition. Indicators 100% free of toxic heavy metals. Instructions For Use: Place a Integron® IT12 Chemical Integrator along with the material to be sterilized in a suitable package according to the recommended sterilization techniques. Place the indicators in those areas of most difficult access to the sterilizing agent. Perform the sterilization cycle. After the sterilization process has finished and evacuation/ventilation process is over, you may:               A. Remove the integrator indicator taking the necessary precaution to avoid                          contact with the remaining sterilizing agent.              B. Ventilate the load together with the integrator indicator and then perform                        the reading. Analyze the results. If the SAFE integration condition has been reached, the        sterilization process has been effective. Specifications: Process: Ethylene Oxide Initial Color: Level 1 Red, Level 2 purple-brown Final Color: Level 1 Yellow, level 2 Green Indicator Type: Type 5 chemical indicator Regulations: ISO 11140-1 More Info About This Product: Color Chart

    SKU: IT12

    $18.99 $15.99

  • Sale -22% Chemical Integrator W/Extender, Steam, Moving Front Type 5, 250/Bg

    Terragene Chemical Integrator W/Extender, Steam, Moving Front Type 5, 250/Bg

    IT26-C Extender/ Moving front Chemical Integrator to monitor Steam sterilization processes between 118°C and 138°C. Control of Steam sterilization processes between 118 °C and 138 °C. Characteristics: Type 5 Integrating Indicator (according to ISO 11140-1). Size: 52 mm x 21 mm. Chemical Integrator consists of a paper wick and a steam and temperature sensitive chemical pellet contained in a paper/film/foil laminate. The chemical pellet melts and migrates as a dark bar along the paper wick. The migration is visible through a zone marked ACCEPT or REJECT, thus indicating whether sterilization conditions were met. The extent of migration depends on steam quality, time, and temperature. The ACCEPT result is reached when a theoretical spore population reaches its kill time, indicating integration condition has been reached. This condition is calibrated with the kill time of 106 Geobacillus stearothermophilus spore population, calculated in BIER (Biological Indicator Evaluator Resistometer). Conditions: saturated steam at 121 °C, 128 °C, 135 °C. Optionally, the readout of the chemical indicator can be done using Trazanto Automatic Quality Control and Traceability System (see instructions for use in device´s manual). Instructions For Use: Carefully open the package and remove only the number of indicators needed. Reseal the package tightly. Place a Integron® IT26-C indicator in each pack, peel pouch, container system or tray to be steam sterilized in the most inaccessible area to sterilizing agent. Perform de sterilization cycle. 4After the sterilization process has finished, the dark bar should have reached the ACCEPT zone. If the dark bar has not reached the ACCEPT zone, a REJECT result is indicated and the items in the pack, peel pouch, container system, or tray were not exposed to proper steam sterilization conditions. These items should be reprocessed according to established procedures and a new IT26-C has to be used. NOTE: In some extended or wet steam cycles, the dark bar can display discoloration in some zones of the reading window, imposing a difficulty for result´s interpretation (see Result Reference Guide for reference). Despite this, regarding cycle integration parameters, this process can be considered as accepted. In case the IT26-C indicator shows a damp appearance after the sterilization process, Terragene® recommend planning an equipment´s maintenance.

    SKU: IT26-C EXT

    $40.99 $31.99

  • Sale -17% Steam Chemical Integrator, 250/Bg Steam Chemical Integrator, 250/Bg

    Terragene Steam Chemical Integrator, 250/Bg

    IT26-C / Moving front Chemical Integrator to monitor Steam sterilization processes between 118°C and 138°C. Control of Steam sterilization processes between 118 °C and 138 °C. Characteristics: Type 5 Integrating Indicator (according to ISO 11140-1). Size: 52 mm x 21 mm. Chemical Integrator consists of a paper wick and a steam and temperature sensitive chemical pellet contained in a paper/film/foil laminate. The chemical pellet melts and migrates as a dark bar along the paper wick. The migration is visible through a zone marked ACCEPT or REJECT, thus indicating whether sterilization conditions were met. The extent of migration depends on steam quality, time, and temperature. The ACCEPT result is reached when a theoretical spore population reaches its kill time, indicating integration condition has been reached. This condition is calibrated with the kill time of 106 Geobacillus stearothermophilus spore population, calculated in BIER (Biological Indicator Evaluator Resistometer). Conditions: saturated steam at 121 °C, 128 °C, 135 °C. Optionally, the readout of the chemical indicator can be done using Trazanto Automatic Quality Control and Traceability System (see instructions for use in device´s manual). Instructions For Use: Carefully open the package and remove only the number of indicators needed. Reseal the package tightly. Place a Integron® IT26-C indicator in each pack, peel pouch, container system or tray to be steam sterilized in the most inaccessible area to sterilizing agent. Perform de sterilization cycle. After the sterilization process has finished, the dark bar should have reached the ACCEPT zone. If the dark bar has not reached the ACCEPT zone, a REJECT result is indicated and the items in the pack, peel pouch, container system, or tray were not exposed to proper steam sterilization conditions. These items should be reprocessed according to established procedures and a new IT26-C has to be used. Despite this, regarding cycle integration parameters, this process can be considered as accepted. In case the IT26-C indicator shows a damp appearance after the sterilization process, Terragene® recommend planning an equipment´s maintenance. Specifications: Process: Steam Indicator Type: Type 5 chemical indicator Regulations: ISO 11140-1 More Info About This Product: User Manual

    SKU: IT26-C

    $45.99 $37.99

  • Sale -24% Multivariable Process Indicator Strip, Type 4 For Plasma Or Vaporized Hydrogen Peroxide

    Terragene Multivariable Process Indicator Strip, Type 4 For Plasma Or Vaporized Hydrogen Peroxide

    CD40 / Multi-variable Chemical Indicator, strips printed with reactive ink for Plasma or Vaporized Hydrogen Peroxide sterilization processes. Control of plasma or vaporized H2O2 sterilization processes. Conditions: 6 minutes, 50 °C, 2,3 mg/l H2O2. Characteristics: Type 4 Chemical Indicator (according to ISO 11140-1). Strips printed with indicator ink. Size: 105 x 18 mm (approximate). Initial color: Purple. Final color: Green. 100 % Toxic Heavy Metals free. Instructions For Use: Place a Chemdye® CD40 Multivariable Process Indicator within each package, bag or tray that will be sterilized by Plasma or Vaporized Hydrogen Peroxide. In rigid containers, place the indicator in every corner, or at least two diagonally opposite corners, to ensure that the sterilization agent has reached the most inaccessible areas. Perform the sterilization cycle. After the sterilization process has finished, remove the indicators from the sterilizer and analyze the results. For all the chemical indicators exposed to Plasma or Vaporized Hydrogen Peroxide, the ink must turn to the green or lighter reference color when the sterilization parameters are reached. Specifications: Process: Hydrogen peroxide Initial Color: Purple Final Color: Green Indicator Type: Type 4 chemical indicator Regulations: ISO 11140-1 More Info About This Product: Color Chart

    SKU: CD40

    $20.99 $15.99

  • Sale -6% Process indicator strip, Type 1 For Plasma or Vaporized Hydrogen Peroxide Process indicator strip, Type 1 For Plasma or Vaporized Hydrogen Peroxide

    Terragene Process indicator strip, Type 1 For Plasma or Vaporized Hydrogen Peroxide

    Chemical Indicator, strips printed with reactive ink for Plasma or Vaporized Hydrogen Peroxide sterilization processes.Internal Control. Metals Free. Chemdye® CD42 Process Indicators (Type 1 according to ISO 11140-1:2014 standard) are single-use chemical indicators that consist of plastic strips printed with indicator ink. These indicators have been designed to monitor Plasma or Vaporized Hydrogen Peroxide sterilization processes within loads, ensuring an adequate exposure to the sterilizing agent during the sterilization process and allowing to distinguish between processed and unprocessed items. Innovative highly sensitive red ink was developed to turn to yellow when the indicator is exposed to Plasma or Vaporized Hydrogen Peroxide. Endpoint condition: 50 ºC, 6 minutes, 2.3 mg/l H2O2. Indicators 100% free of toxic heavy metals. Instructions For Use: Place a Chemdye® CD42 Process Indicator within each package, bag or tray that will be sterilized by Plasma or Vaporized Hydrogen Peroxide. In rigid containers, place the indicator in every corner, or at least two diagonally opposite corners, to ensure that the sterilization agent has reached the most inaccessible areas. Perform the sterilization cycle. After the sterilization process has finished, remove the indicators from the sterilizer and analyze the results. For all the chemical indicators exposed to Plasma or Vaporized Hydrogen Peroxide, the ink must turn to the yellow reference color when the sterilization parameters are reached. For reference color, please refer to Result Reference Guide. More Info About This Product: Color Chart

    SKU: CD42

    $15.99 $14.99

  • Sale -19% Quattro Sterilization Pouch, 200/Bx, 6 Bx/Cs Quattro Sterilization Pouch, 200/Bx, 6 Bx/Cs

    Medicom Quattro Sterilization Pouch, 200/Bx, 6 Bx/Cs

    SafeSeal® Quattro sterilization pouches are made from high quality porous medical paper and mechanically sealed with TruePress™ technology. The perforated fold facilitates precise folding of a wide self-adhesive strip to form an airtight seal. Internal and external multiparameter process indicators for steam sterilization respond to three variables: time, temperature and saturated steam. The multiparameter process indicators printed directly on the pouch confirm sterilization parameters. Blue-tinted film makes it easy to view instruments and detect punctures or tears. Convenient thumb notch makes it easy to open the pouch without contaminating the contents.

    SKU: 88000-4

    $65.99 - $125.99

  • Sale -27% Quattro Sterilization Pouch, 200/Bx, 10 Bx/Cs Quattro Sterilization Pouch, 200/Bx, 10 Bx/Cs

    Medicom Quattro Sterilization Pouch, 200/Bx, 10 Bx/Cs

    SafeSeal® Quattro sterilization pouches are made from high quality porous medical paper and mechanically sealed with TruePress™ technology. The perforated fold facilitates precise folding of a wide self-adhesive strip to form an airtight seal. Internal and external multiparameter process indicators for steam sterilization respond to three variables: time, temperature and saturated steam. The multiparameter process indicators printed directly on the pouch confirm sterilization parameters. Blue-tinted film makes it easy to view instruments and detect punctures or tears. Convenient thumb notch makes it easy to open the pouch without contaminating the contents.

    SKU: 88015-4

    $95.99 - $190.99

  • Sale -25% Quattro Sterilization Pouch, 200/Bx, 5 Bx/Cs Quattro Sterilization Pouch, 200/Bx, 5 Bx/Cs

    Medicom Quattro Sterilization Pouch, 200/Bx, 5 Bx/Cs

    SafeSeal® Quattro sterilization pouches are made from high quality porous medical paper and mechanically sealed with TruePress™ technology. The perforated fold facilitates precise folding of a wide self-adhesive strip to form an airtight seal. Internal and external multiparameter process indicators for steam sterilization respond to three variables: time, temperature and saturated steam. The multiparameter process indicators printed directly on the pouch confirm sterilization parameters. Blue-tinted film makes it easy to view instruments and detect punctures or tears. Convenient thumb notch makes it easy to open the pouch without contaminating the contents.

    SKU: 88005-4

    $52.99 - $399.99

  • Sale -20% Sterilization Pouch, 10" x 15", 200/bx

    Sultan Sterilization Pouch, 10" x 15", 200/bx

    Advanced Sterilization Pouch: Elevate Your Sterilization Procedures Introducing our Sterilization Pouch, sized 10" x 15", a must-have for every medical and dental facility. With a focus on convenience, efficiency, and compliance, this product is designed to elevate your sterilization processes.What sets our pouch apart is its unique peel-off indicator that ensures thorough heat penetration within the pouch. Bid farewell to purchase secondary indicator strips – our pouch is a self-sufficient solution. It conveniently affixes to patient files, creating a permanent sterilization record, and aligning with CDC requirements for internal indicators.Crafted to the highest standards, our pouch boasts dual external heat and gas sterilization indicators, providing double assurance of successful sterilization. Certified for a remarkable minimum 5-year post-sterilization lifespan, it guarantees prolonged reliability.The aqua-tinted, transparent four-ply film allows easy identification of instrument setups, enabling swift recognition of compromised sterility. Coupled with medical-grade paper, this pouch enables optimal steam and gas penetration. Quality seals bolster its strength while ensuring a clean, fiber-free peel.

    SKU: 83020

    $93.99 $74.99

  • Sale -17% Sterilization Pouch, 11" x 16", 100/bx

    Sultan Sterilization Pouch, 11" x 16", 100/bx

    Revolutionize Sterilization with Our State-of-the-Art 11" x 16" Sterilization Pouch: Unmatched Quality and Innovation Introducing our Sterilization Pouch, 11" x 16", a pinnacle of innovation and reliability for your sterilization needs. With a unique peel-off indicator, this pouch takes the guesswork out of sterilization. The indicator confirms heat penetration within the pouch, eliminating the need for secondary indicator strips. It seamlessly affixes to the patient file, ensuring a permanent record of the sterilization process.Meeting CDC requirements, our pouch features dual external heat and gas sterilization indicators. The certification for a minimum 5-year post-sterilization life underscores its longevity. The aqua-tinted, see-through, four-ply film enables swift instrument identification and allows for immediate assessment of sterility. Crafted from medical-grade paper, it enables thorough steam and gas penetration.Our pouch boasts quality seals that not only enhance its durability but also guarantee a clean, fiber-free peel. The easy-to-open overlap design streamlines your workflow. With a wide range of sizes tailored to various indications, it accommodates your diverse needs.Trust in a product that combines cutting-edge features, uncompromising quality, and adherence to the highest standards. Elevate your sterilization practices with our advanced pouch – an assurance of safety, efficiency, and peace of mind.

    SKU: 83080

    $63.99 $52.99

  • Sale -15% Sterilization Pouch, 12" x 18", 100/bx

    Sultan Sterilization Pouch, 12" x 18", 100/bx

    Unparalleled Sterilization Confidence: Introducing our 12" x 18" Sterilization Pouch with Innovative Peel-Off Indicator Introducing our Sterilization Pouch, sized at 12" x 18", available in a convenient pack of 100. Designed to revolutionize your sterilization process, this pouch boasts a unique peel-off indicator that eliminates the need for separate indicator strips. Watch with confidence as the indicator confirms thorough heat penetration within the pouch, ensuring optimal sterilization without compromise.Crafted to meet CDC requirements, this pouch features an internal indicator for each package, streamlining your compliance process. The innovative dual external heat and gas sterilization indicators further reinforce its reliability. With a certified minimum 5-year post-sterilization life, rest assured that your instruments remain impeccably sterilized until use.Its aqua-tinted, four-ply film allows for effortless identification of instrument setups while safeguarding sterility. The robust medical-grade paper facilitates seamless steam and gas penetration. Quality seals augment the pouch's strength and offer a pristine, fiber-free peel every time.The pouch's user-friendly overlap design ensures easy opening, saving crucial moments in critical situations. With a range of sizes catering to diverse needs, this sterilization pouch stands as the pinnacle of safety and convenience. Elevate your sterilization procedures and uphold the highest standards of quality with this exceptional solution.

    SKU: 83025

    $60.99 $51.99

  • Sale -25% Sterilization Pouch, 2¼" x 4", 200/bx

    Sultan Sterilization Pouch, 2¼" x 4", 200/bx

    Advanced Sterilization Pouch: Confidence in Protection and Precision Introducing our Sterilization Pouch, sized at 2¼" x 4", a true game-changer for your medical and dental sterilization needs. This remarkable product boasts a unique peel-off indicator, eliminating the necessity for additional indicator strips. With this innovation, you can effortlessly confirm heat penetration within the pouch, ensuring impeccable sterilization.Crafted to meet the rigorous demands of healthcare facilities, this pouch firmly adheres to patient files, creating an enduring record of sterilization procedures. Complying with CDC mandates, it integrates an internal indicator, guaranteeing precision in each package.Equipped with dual external heat and gas sterilization indicators, this pouch is your steadfast partner in upholding safety standards. Its certification for a minimum 5-year post-sterilization lifespan showcases its durability and reliability.Crafted with an aqua-tinted, transparent four-ply film, the pouch allows easy identification of instrument setups while offering a quick assessment of sterility status. Its robust, medical-grade paper ensures thorough steam and gas penetration, while quality seals amplify strength and a pristine, fiber-free peel.

    SKU: 83001

    $19.99 $14.99

  • Sale -23% Sterilization Pouch, 2¾" x 10", 200/bx

    Sultan Sterilization Pouch, 2¾" x 10", 200/bx

    "Innovative Sterilization Pouch: Streamlined Confidence for Your Sterilization Process" Introducing our Sterilization Pouch, sized at 2¾" x 10", available in a convenient pack of 200. Revolutionize your sterilization process with this advanced solution that ensures the utmost confidence and convenience.Designed with precision, this pouch boasts a unique peel-off indicator, eliminating the need for separate indicator strips. Watch as it transforms, confirming thorough heat penetration within the pouch during sterilization cycles. This innovation aligns with CDC requirements, eliminating the guesswork and streamlining your process.Crafted for excellence, our pouch affixes effortlessly to patient files, offering a permanent sterilization record. The inclusion of dual external heat and gas sterilization indicators guarantees accuracy, while its remarkable certification for a minimum 5-year post-sterilization lifespan promises longevity.Through its aqua-tinted, four-ply film, you can effortlessly assess instrument setups and detect any compromise in sterility. The medical-grade paper, designed for steam and gas penetration, ensures robust performance. Quality seals reinforce strength, culminating in a fiber-free peel through the easy-to-open overlap design.

    SKU: 83003

    $21.99 $16.99

  • Sale -22% Sterilization Pouch, 3¼" x 6½", 200/bx

    Sultan Sterilization Pouch, 3¼" x 6½", 200/bx

    "Innovative Sterilization Confidence: Introducing our Advanced 3¼" x 6½" Sterilization Pouch - 200/bx" Introducing our Sterilization Pouch, sized at 3¼" x 6½", available in a convenient pack of 200. Designed with meticulous attention to detail, this pouch is a paramount addition to your medical facility or dental practice.Crafted with innovation in mind, this pouch features a unique peel-off indicator that revolutionizes the sterilization process. With its smart design, it ensures absolute heat penetration within the pouch, eliminating the need for secondary indicator strips. Furthermore, this indicator conveniently adheres to the patient's file, creating a permanent record of the sterilization process, and fostering accountability and compliance.Exceeding the stringent standards set by the CDC, our pouch includes dual external heat and gas sterilization indicators, offering an added layer of assurance. Certified for a remarkable minimum 5-year post-sterilization life, this product is synonymous with reliability.The aqua-tinted, see-through four-ply film empowers you to effortlessly inspect instrument setups while also facilitating the identification of any potential compromise in sterility. Its robust medical-grade paper allows seamless steam and gas penetration, while the quality seals augment strength and deliver a clean, fiber-free peel.

    SKU: 83000

    $22.99 $17.99

  • Sale -24% Sterilization Pouch, 3½" x 10", 200/bx

    Sultan Sterilization Pouch, 3½" x 10", 200/bx

    Advanced Sterilization Pouch: Ensuring Unrivaled Safety and Convenience Introducing our Sterilization Pouch, sized perfectly at 3½" x 10", offering exceptional sterilization assurance and convenience. With its ingenious peel-off indicator, your worries about heat penetration are put to rest. This unique feature eliminates the need for purchasing additional indicator strips, saving you time and resources.Designed to streamline record-keeping, the peel-off indicator can be affixed to the patient's file, providing a permanent record of the sterilization process. Meeting CDC requirements, the pouch boasts dual external heat and gas sterilization indicators, ensuring the highest level of safety.What sets this pouch apart is its post-sterilization longevity, certified for a remarkable minimum 5-year lifespan. The aqua-tinted, transparent four-ply film grants you visibility into instrument setups while allowing you to swiftly identify any potential compromise in sterility.Crafted from robust, medical-grade paper, this pouch enables thorough steam and gas penetration, while quality seals enhance its strength, ensuring a clean, fiber-free peel. The user-friendly overlap design guarantees easy opening, saving you precious time in critical moments.

    SKU: 83005

    $24.99 $18.99

  • Sale -23% Sterilization Pouch, 5¼" x 7½", 200/bx

    Sultan Sterilization Pouch, 5¼" x 7½", 200/bx

    Unparalleled Sterilization Confidence: Introducing our Innovative 5¼" x 7½" Sterilization Pouch Introducing our Sterilization Pouch, 5¼" x 7½", the ultimate solution for your medical sterilization needs. With unique features that set it apart, this product ensures the highest level of safety and convenience.The standout feature is the innovative peel-off indicator that confirms thorough heat penetration within the pouch. No more need for separate indicator strips – this pouch is an all-in-one solution. The indicator also affixes to patient files, providing a permanent sterilization record as per CDC requirements.Crafted to perfection, our pouch boasts dual external heat and gas sterilization indicators, guaranteeing the utmost reliability. It's certified for a remarkable minimum 5-year post-sterilization life, assuring longevity and peace of mind.The aqua-tinted, four-ply film offers transparency, allowing you to easily identify instrument setups and assess sterility without compromising it. The medical-grade paper enables optimal steam and gas penetration while maintaining strength.Enhanced by quality seals for added durability and a clean, fiber-free peel, the easy-to-open overlap design ensures effortless usability. Available in a wide range of sizes, our Sterilization Pouch caters to all indications, making it an indispensable asset for various medical settings.

    SKU: 83075

    $42.99 $32.99

  • Sale -19% Sterilization Pouch, 5½" x 13", 200/bx

    Sultan Sterilization Pouch, 5½" x 13", 200/bx

    Premium Sterilization Pouch: Ensuring Uncompromised Healthcare Safety Introducing our Sterilization Pouch, sized at 5½" x 13", available in a convenient pack of 200. This innovative pouch is meticulously crafted to meet the stringent demands of modern healthcare facilities.Designed with efficiency and reliability in mind, this pouch boasts a unique peel-off indicator that provides instant confirmation of optimal heat penetration within. Bid farewell to the need for secondary indicator strips, as this pouch eliminates that requirement. Moreover, it effortlessly affixes to patient files, ensuring a permanent sterilization record.Meeting CDC standards, this pouch features dual external heat and gas sterilization indicators. Its exceptional certification guarantees a minimum 5-year post-sterilization lifespan, contributing to long-term operational excellence. The aqua-tinted, see-through, four-ply film empowers users to identify instrument setups and gauge sterility status at a glance.Crafted from robust medical-grade paper, this pouch enables seamless steam and gas penetration while maintaining its structural integrity. The quality seals further reinforce its strength, ensuring a clean, fiber-free peel every time. The easy-to-open overlap design streamlines process while the wide range of available sizes caters to diverse needs.Upgrade your sterilization practices with confidence using this advanced pouch. It's not just a pouch; it's a testament to uncompromising quality, lasting performance, and unwavering dedication to safety in healthcare settings.

    SKU: 83045

    $46.99 $37.99

  • Sale -20% Sterilization Pouch, 7" x 13", 200/bx

    Sultan Sterilization Pouch, 7" x 13", 200/bx

    Premium Sterilization Pouch: Unmatched Safety and Convenience for Medical Practices Introducing our Sterilization Pouch, 7" x 13", a reliable solution for maintaining impeccable sterilization standards in medical and dental settings. With its cutting-edge features and adherence to stringent guidelines, this pouch guarantees the safety of your instruments and peace of mind for your practice.The standout feature of this pouch is its unique peel-off indicator that revolutionizes the sterilization process. Say goodbye to purchasing secondary indicator strips – our pouch includes a built-in indicator that confirms optimal heat penetration within the pouch. This not only saves you time and resources but also ensures foolproof sterilization without compromise.Designed to meet CDC requirements, our pouch affixes effortlessly to patient files, creating a permanent record of the sterilization process. Dual external heat and gas sterilization indicators provide an extra layer of confidence.Crafted from a strong, medical-grade paper that allows seamless steam and gas penetration, and coupled with quality seals for enhanced strength, these pouches boast a clean, fiber-free peel. The easy-to-open overlap design streamlines the workflow, while the aqua-tinted, see-through, four-ply film allows instant identification of instrument setups and assessment of sterility status.

    SKU: 83015

    $58.99 $46.99

  • Sale -21% Sterilization Pouch, 7½" x 13", 200/bx

    Sultan Sterilization Pouch, 7½" x 13", 200/bx

    Premium Sterilization Pouches: Safeguarding Hygiene for Your Practice Introducing our Sterilization Pouch, designed to ensure the utmost safety and hygiene in your medical or dental practice. With dimensions of 7½" x 13", these pouches provide ample space to accommodate a variety of medical instruments while maintaining their sterile integrity.Each box contains 200 pouches, offering an efficient solution to your sterilization needs. Our pouches are constructed using high-quality, medical-grade materials that effectively seal and protect your instruments from contaminants, ensuring they remain in a pristine condition until they're ready for use. The transparent front surface allows easy visibility, enabling quick instrument identification without compromising the sterilized environment.These pouches are equipped with an easy-to-use self-sealing adhesive strip, eliminating the need for additional equipment or heat sealing. Whether you're running a bustling hospital or a small clinic, our sterilization pouches provide the reliability and convenience you require.Prioritize the safety of your patients and the integrity of your practice with our dependable Sterilization Pouches. With 200 pouches per box, you're making a lasting investment in maintaining a sterile environment for your valuable instruments. Trust in our product to deliver impeccable results, every time.

    SKU: 88020

    $38.99 $30.99

  • Sale -11% Sterilization Pouches 2-1/4 x 5 Sterilization Pouches 2-1/4 x 5

    Dukal Sterilization Pouches 2-1/4 x 5

    Easy to read “Color Changing Indicators” printed on each pouch assuring proper sterilization process by Steam and Ethylene Oxide. Clean separation (peeling) of the 4-ply see-thru film from the medical grade paper maintains sterility of contents until their use. Blue Tinted Transparent Film for easier identification of contents and possible punctures by contrast of color Tripple heat sealed for a seal that is consistent and strong. Attributes Brand Name Unipack Size 2-1/4 x 5 Sterile No Weight 7.8705 lbs Packaging Packaging 200/BX Inner Packaging 200/BX Case Packaging 200/BX, 16 BX/CS Total Case Quantity 3200 Inner Packaging Barcode D784UPP2251

    SKU: UPP-225

    $64.32 $57.43

Login

Forgot your password?

Don't have an account yet?
Create account