53 products

  • Sale -15% PCD, Ultra Rapid W/BI (20Min) For Steam, 25 Bis + 25 PCDs/Kt PCD, Ultra Rapid W/BI (20Min) For Steam, 25 Bis + 25 PCDs/Kt

    Terragene PCD, Ultra Rapid W/BI (20Min) For Steam, 25 Bis + 25 PCDs/Kt

    KPCD224-C / Test Pack PCD Kit. Process Challenge Device for Steam sterilization processes with moving-front Type 5 Integrator and Bionova® Ultra Rapid Self-contained Biological Indicator BT224, plus Bionova® BT224 Biological Indicators Positive Control. Class 5 spores per strip. For routine load release, especially for loads containing implants. For routine sterilizer monitoring. For periodic validation of the sterilizer (after installation, repair, relocation). Detects inadequate air removal and steam penetration in dynamic- airremoval (pre-vacuum) and gravity displacement, steam autoclaves between 132-135 ºC. Characteristics: The kit Consists Of: PCD224-C: Porous Cards System Holding: A Self-contained Biological Indicator Bionova® BT224.A Type 5 chemical indicator Integron® IT26-C (moving-front integrator). A self-adhesive Record Card, PCDBI-C-RC, where data on sterilization cycle may be written. Self-contained Biological Indicator Bionova® BT224 (to be used as a positive control) Specifications: Initial Color: Blue. Final Color: Dark Grey or Black. Process: Steam Microorganism: Geobacillus stearothermophilus (ATCC 7953) Population: 10^6 Spores/carrier Read-Out Time: 20 min Regulations: ANSI/AAMI ST79, ISO 11138-3, ISO 11140-1 IT26-C Integrator Indicator (within the challenge device): The migration is visible through a zone marked ACCEPT or REJECT, thus indicating whether sterilization conditions were met. Integration condition is calibrated against the kill time of a 106 G. stearothermophilus ATCC 7953 spore population, calculated in BIER (Biological Indicator Evaluator Resistometer). Conditions: saturated steam at 121 ºC, 128 ºC, 135 ºC. BT224 Self-contained Ultra Rapid Biological Indicator (within the challenge device): 106 G. stearothermophilus ATCC 7953 spores per vial in paper carrier. Glass ampoule with growth indicator medium. Label with chemical indicator line printed with Steam reactive ink (Color change: pink to brown) Final results: by fluorescence after incubation for 20 minutes at 60 ºC (sensitivity 97%). An optional visual pH color change confirmation could be made after 48 hours of incubation. A 7-day readout is optional to confirm 20-minutes results by color change. Note: If sterilization process was not successful, indicator medium will turn yellow after incubation, thus indicating the presence of living G. stearothermophilus spores. If sterilization process was successful, indicator medium will remain purple after incubation.

    SKU: KPCD224-C

    $260.99 $220.99

  • Sale -24% Strip Integrator EO, 500/Bg Strip Integrator EO, 500/Bg

    Terragene Strip Integrator EO, 500/Bg

    CD16 / Multi-variable Chemical Indicators, double card strips printed with reactive ink for Ethylene Oxide sterilization processes. Metals Free. Control of Ethylene Oxide (EO) sterilization processes. Conditions: 600 mg/l EO, RH 60%, 30 °C, 30 minutes // 600 mg/l EO, RH 60%, 54 °C, 20 minutes. Characteristics: Type 4 Chemical Indicator (according to ISO 11140-1). Double punched card strips printed with indicator ink. Specifications: Size: 200 x 15 mm. Initial Color: Purple/Brown. Final Color: Green. 100 % Toxic Heavy Metals free. Instructions For Use: Place a Chemdy® CD16 Multivariable Process Indicator within each package, bag or tray that will be sterilized by Ethylene Oxide. In rigid containers, place the indicator in every corner, or at least two diagonally opposite corners, to ensure mthat the sterilization agent has reached the most inaccessible areas. Perform the sterilization cycle. After the sterilization process has finished, remove the indicators from the sterilizer and analyze the results. For all the chemical indicators exposed to Ethylene Oxide, the ink must turn to the green reference color when the sterilization parameters are reached. More Info About This Product: Color Chart

    SKU: CD16

    $20.99 $15.90

  • Sale -19% Strip Integrator Steam, 500/Bg Strip Integrator Steam, 500/Bg

    Terragene Strip Integrator Steam, 500/Bg

    Multi-variable Chemical Indicator printed with reactive ink for Steam sterilization processes. Chemdye® CD29 Multivariable Process Indicators (Type 4 according to ISO 11140-1:2014 standard) are single-use chemical indicators that consist of one-side laminated punched paper double strips printed with indicator ink. These indicators have been designed to monitor Steam sterilization processes within loads, ensuring an adequate exposure to the sterilizing agent during the sterilization process and allowing to distinguish between processed and unprocessed items. Innovative highly sensitive yellow ink was developed to turn to dark brown/black when the indicator is exposed to Steam considering the critical process variables which provides additional quality assurance. Endpoint condition: 121 °C, 15 minutes; 134 °C, 3.5 minutes. Indicators 100 % free of toxic heavy metals. Instructions For Use: Place a Chemdye® CD29 Multivariable Process Indicator within each package, bag or tray that will be sterilized by Steam. In rigid containers, place the indicator in every corner, or at least two diagonally opposite corners, to ensure that the sterilization agent has reached the most inaccessible areas. Perform the sterilization cycle. After the sterilization process has finished, remove the indicators from the sterilizer and analyze the results. For all the chemical indicators exposed to Steam, the ink must turn to the dark brown/black reference color when the sterilization parameters are reached. For reference color, please refer to Result Reference Guide. Specifications: Process: Steam Initial Color: Yellow Final Color; Black Indicator Type: Type 4 chemical indicator Regulations: ISO 11140-1 More Info About This Product: Color Chart

    SKU: CD29

    $15.99 $12.99

  • Sale -25% Thermal Paper Roll For IC10/20FR And IC10/20FRLCD, 6rl/Bg

    Terragene Thermal Paper Roll For IC10/20FR And IC10/20FRLCD, 6rl/Bg

    ICTP / Incubator Thermal Paper. Accessory for the IC10/20FR and IC10/20FRLCD incubator€™s thermal printer. Thermal Paper specially designed for using with Bionova® IC10/20FR, and Bionova® IC10/20FRLCD Auto-Reader€™s Printer. Specifications: Thermal Paper Roll. Color: white Paper length: 30 m. Paper width: 57 mm. Roll external diameter: 50 mm. Roll internal diameter: 13.4 mm. Its function is to record the final results of biological indicators subjected to sterilization process and quantitative analysis of hygiene monitoring systems at each activated position of IC10/20FR or IC10/20FRLCD, which allows registration into your sterilization record keeping book. Read IC10/20FR or IC10/20FRLCD directions for use, as appropriate.

    SKU: ICTP_BION_6

    $50.99 $37.99

  • Sale -24% Thermal Paper Roll For Minibio, 3Rl/Bg

    Terragene Thermal Paper Roll For Minibio, 3Rl/Bg

    ICTP Mini / Thermal Paper specially designed for using with Bionova® Mini Bio, Bionova® Mini Pro Auto-Reader€™s Printer.Thermal Paper specially designed for using with Bionova® Mini Bio, Bionova® Mini Pro Auto-Reader€™s Printer. Specifications: Thermal Paper Roll. Color: White Paper Length: 4.7 m. Paper Width: 57 mm. Roll External Diameter: 23 mm. Roll Internal Diameter: 13.4 mm. Its function is to record the final results of biological indicators subjected to sterilization process and quantitative analysis of hygiene monitoring systems at each activated position of Bionova® Mini Bio and Mini Pro incubators, which allows record keeping in your sterilization records book. Read Bionova® Mini Bio and Mini Pro directions for use, as appropriate.

    SKU: ICTP MINI

    $40.99 $30.99

Medical Supplies | Shop now | Available only at SurgiMac
Hospitals and other medical facilities can negotiate directly with SurgiMac to buy supplies for large group purchases. 

Medical Supplies

Login

Forgot your password?

Don't have an account yet?
Create account